V-cone flowmeter
Technical parameters of XVC V-cone flowmeter1.Low requirements on installation: straight tube 0-3D in the front and straight tube 0-1D in the rear2.Ratio of range: 10:1 (usually); the maximal proper parameter: 50:13.Small damage due to the pressing: the damage is 1/31/5 that of the pore plate when the value of β remains the same
4.Strong resistance against wear: After the streamline V cone is throttled, the vacuum effect will be generated on the surface of V cone to keep the V cone from being worn easily.5.Being free from blockage and adhesion: the complete purging design of V cone avoids the settlement of residue, coagulation or particle.6.Long-standing favorable stability: the value of β can remain the same for long and the accurateness in measurement can be ensured for a long period.7.High precision: 0.5 grade8.Good repeatability: more than 0.19.Stable signal: singular fluctuation is 1/10 of that of pore plate10.Wide range of the value of β: the unique geometrical shape of V cone flow sensor allows wide range of the value of β11.Wide range of caliber: DN25DN200012.The ability to measure high temperature and high-pressure medium: maximal working .temperature: 850; maximal pressure: 40MPa13.The ability to measure the dirty medium (coke-oven gas, blast furnace gas, feed stock and residual oil)........14.The ability to measure gas and liquid two-phase medium (moisture and condensed water)....
V-cone flowmeter